Feature Type
End unit which emits useful energy (e.g. heat, cool) in the zone where it is required.
Attribute type: core:creationDate |
Date the city object was generated.
0..1
Date
Attribute type: core:terminationDate |
????
0..1
Date
Attribute type: core:externalReference |
Reference to a corresponding object in another information system, for example in the German cadastre (ALKIS), the German
topographic information system (ATKIS), or the OS MasterMap®.
0..*
ExternalReference (DataType)
Attribute type: core:relativeToTerrain |
Location of the city object relative to the surrounding terrain.
0..1
RelativeToTerrain (Enumeration)
Code |
Text |
|
entirelyAboveTerrain |
entirelyAboveTerrain |
Object is located entirely above terrain.
|
substantiallyAboveTerrain |
substantiallyAboveTerrain |
Most, but not all parts of the object are located above terrain.
|
substantiallyAboveAndBelowTerrain |
substantiallyAboveAndBelowTerrain |
Parts of the object are located above terrain, and other parts below terrain.
|
substantiallyBelowTerrain |
substantiallyBelowTerrain |
Most, but not all parts of the object are located below terrain.
|
entirelyBelowTerrain |
entirelyBelowTerrain |
All parts of the object are located below terrain.
|
Attribute type: core:relativeToWater |
Location of the city object relative to the surrounding water surface.
0..1
RelativeToWater (Enumeration)
Code |
Text |
|
entirelyAboveWaterSurface |
entirelyAboveWaterSurface |
Object is located entirely above water surface..
|
substantiallyAboveWaterSurface |
substantiallyAboveWaterSurface |
Most, but not all parts of the object are located above water surface.
|
substantiallyAboveAndBelowWaterSurface |
substantiallyAboveAndBelowWaterSurface |
Parts of the object are located above water surface, and other parts below water surface.
|
substantiallyBelowWaterSurface |
substantiallyBelowWaterSurface |
Most, but not all parts of the object are located below water surface.
|
entirelyBelowWaterSurface |
entirelyBelowWaterSurface |
All parts of the object are located below water surface.
|
temporarilyAboveAndBelowWaterSurface |
temporarilyAboveAndBelowWaterSurface |
The height of the water surface is varying and the object temporily is located above or below water level.
|
Attribute type: core:appearance |
0..*
AbstractAppearance
Attribute type: core:genericAttribute |
Additional property of the city object
0..*
AbstractGenericAttribute (DataType)
Attribute type: energy:numberOfDevices |
Indicates the total number of devices used.
0..1
Integer (Type)
Attribute type: energy:model |
Indicates the type of model.
0..1
CharacterString (Type)
Attribute type: energy:serviceLife |
Relation to a data structure describing the service life for lifecycle analysis.
0..1
ServiceLife
Attribute type: energy:yearOfManufacure |
Manufacturing year of the energy system.
0..1
Year
Attribute type: energy:installedIn |
Relation to the city object in which the energy system is installed.
0..*
_CityObject
Attribute type: energy:emitterType |
Type of the energy emitter (e.g. radiators, radiant floor etc.).
0..1
EmitterTypeValue (Enumeration)
Code |
Text |
|
radiator |
radiator |
A unit that radiates or emits light, heat, or sound. |
convector |
convector |
A heating appliance that circulates warm air by convection. |
radiantFloor |
radiantFloor |
Radiant floor heating systems supply heat directly to the floor of a house. |
radiantCeiling |
radiantCeiling |
diant floor heating systems supply heat directly to the panels in the ceiling of a house. |
radiantWall |
radiantWall |
Radiant floor heating systems supply heat directly to the panels in the wall of a house. |
splitUnit |
splitUnit |
A split unit consists of two main parts: the outdoor unit and the indoor unit. The outdoor unit is installed on or near the wall outside of the room or space that you wish to cool. |
2PipesFanCoilUnit |
2PipesFanCoilUnit |
The 2-pipe system consists of a single water coil connected to two pipes (supply and return) and one valve that can serve as either chill water coil or hot water coil depending on the mode of the system. This type of fan coil cannot cool and heat at the same time and is dependent of the actual mode of the building. |
4PipesFanCoilUnit |
4PipesFanCoilUnit |
The 4-pipe system consists of two separate cooling and heating water coils. Each coil has its own dedicated set of pipes (supply and return) and valve. This type of fan coil can cool and heat at the same time and is not dependent of the actual mode of the building. |
Attribute type: energy:installedPower |
Total nominal power of the emitter units.
0..1
Measure (Type)
Attribute type: energy:thermalExchange |
Proportion of the different thermal exchanges (e.g. convection, radiative etc.).
0..1
HeatExchangeType
Attribute type: energy:emitts |
Amount of energy being emitted via a specific energy carrier.
0..*
EnergyFlow